This last-generation handpiece is the result of our ongoing research and development work. PM 1:1 is designed to withstand the stresses resulting from repeated lateral pressure, while maintaining exceptional precision. You will appreciate the absence of vibration, quiet operation and tried and tested bur locking system.

Description

PM 1:1

This last-generation handpiece is the result of our ongoing research and development work. PM 1:1 is designed to withstand the stresses resulting from repeated lateral pressure, while maintaining exceptional precision. You will appreciate the absence of vibration, quiet operation and tried and tested bur locking system.

Technology

Micro-Series. Welcome to a New Dimension.

Bien-Air’s new generation Micro-Series models ally innovation with compact design, resulting in improved power and maneuverability. Up to 30% shorter and 23% lighter than traditional models, they have an easy grasp that allows for optimal work comfort with less strain on the hand, arm, and shoulder.

MicroSeries
MicroSeries

Specifications

TECHNICAL DATA

PM 1:1 Micro-Series PM 1:1 Standard
Type Straight handpiece with internal spray Straight handpiece
Ratio 1:1 (direct) 1:1 (direct)
Coupling Compatible with Micro-Series E-type as per ISO 3964
Locking system Locking ring Locking ring
Bur dimension Bur shank Ø 2.35 mm Bur shank Ø 2.35 mm
Cleaning / sterilisation Thermal washer / steam autoclave up to 135°C (275°F) Thermal washer / steam autoclave up to 135°C (275°F)
Irrigation Internal
Warranty 2 to 3  years 1 2 to 3  years 1
Reference PM 1:1 Micro-Series 1600693-001 PM 1:1 Standard 1600383-001

Downloads

BROCHURE

MANUAL

MAINTENANCE

IMAGES

Maintenance

MAINTENANCE OF CONTRA-ANGLES

PREPARATION

A.REMOVING THE INSTRUMENT

Remove the rotary instrument from the chuck mechanism

Disconnect the contra-angle from the motor

B.PRE-DISINFECTION

External disinfection

Do not immerse the instrument in a disinfectant bath.

CLEANING

A.CLEAN UNDER RUNNING WATER AT <38°C

B.REMOVING DIRT/DEPOSITS

Carefully remove all traces of dirt or deposits from the nozzles using the Bien-Air cleaning wire

Dry the nozzles with compressed air then dry the rest of the instrument with a cloth

Do not immerse in an ultrasonic cleaner

C.INTERNAL AND EXTERNAL CLEANING WITH SPRAYNET

Shake the Spraynet before use

Use the Spraynet attachment 1

Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Spraynet button down for 1 second

Clean the exterior of the contra-angle with a cloth soaked in Spraynet

DISINFECTION

A.DISINFECTION USING SURFACE DISINFECTANT (follow the manufacturer’s instructions for use)

Do not immerse the instrument in a disinfectant bath

OR

B.THERMAL DISINFECTION (follow the manufacturer’s instructions for use)

LUBRICATION

A.LUBRICATION WITH LUBRIFLUID

Shake the Lubrifluid before usen

Use the Lubrifluid attachment 1

Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Lubrifluid button down for 1 second

Then, run an operating test for 30 seconds at low speed to remove any surplus lubricant

Store immediately: store the instruments with the tip pointing downwards so that any oil residues can flow out

STERILISATION

A. PLACE THE CONTRA-ANGLE IN A STERILISATION BAG

B. STERILISE IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS
Instruments bearing the “135°C” can be sterilised in an autoclave

Only sterilise instruments which have been cleaned and lubricated