CA 1:2.5

The new CA 1:2.5 L Micro-Series is the gold standard contra-angle for surgery and periodontics.

Thanks to its speed increasing ratio, the CA 1:2.5 L Micro-Series can be used for a wide range of clinical applications : wisdom tooth extraction, apicectomy, crown lengthening and hemisection.

Description

VERSATILE AND ERGONOMIC

The new CA 1:2.5 L Micro-Series is the gold standard contra-angle for surgery and periodontics.

Thanks to its speed increasing ratio, the CA 1:2.5 L Micro-Series can be used for a wide range of clinical applications : wisdom tooth extraction, apicectomy, crown lengthening and hemisection.

Technology

Specifications

TECHNICAL DATA

CA 1:2.5 L Micro-Series
Transmission ratio 1:2.5
Maximum speed (rpm) 100’000
Head
Head diameter (mm) 9.8
Head size (mm) 15.5 (22.9 mm with bur 19 mm)
Weight (g) 82
Noise level (dBa) 57
Spray system 2 x 3 separate air/water sprays
Lighting system Multi-strand optical glass technology
Coupling ISO 3964 & Bien-Air Micro-Series
Warranty 1  year
Reference CA 1:2.5 L Micro-Series 1601055-001

Maintenance

MAINTENANCE OF CONTRA-ANGLES AND HANDPIECES FOR SURGERY AND IMPLANTOLOGY

PREPARATION

A.REMOVING THE INSTRUMENT

Remove the rotary instrument from the chuck mechanism

Disconnect the contra-angle from the motor

B.PRE-DISINFECTION

External disinfection

Do not immerse the instrument in a disinfectant bath.

CLEANING

A.CLEAN UNDER RUNNING WATER AT <38°C

B.REMOVING DIRT/DEPOSITS

Carefully remove all traces of dirt or deposits from the nozzles using the Bien-Air cleaning wire

Dry the nozzles with compressed air then dry the rest of the instrument with a cloth

Do not immerse in an ultrasonic cleaner

C.INTERNAL CLEANING WITH AQUACARE

Shake the Aquacare before use

Use the Aquacare attachment 1

Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Aquacare button down for 2 seconds

Use the Aquacare attachment 3

Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Aquacare button down for 1 second

D.INTERNAL AND EXTERNAL CLEANING WITH SPRAYNET

Shake the Spraynet before use

Use the Spraynet attachment

Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Spraynet button down for 1 second

Clean the exterior of the contra-angle with a cloth soaked in Spraynet

DISINFECTION

A.DISINFECTION USING SURFACE DISINFECTANT (follow the manufacturer’s instructions for use)

Do not immerse the instrument in a disinfectant bath

OR

B.THERMAL DISINFECTION (follow the manufacturer’s instructions for use)

LUBRICATION

A.LUBRICATION WITH LUBRIFLUID

  • Shake the Lubrifluid before use
  • Use the Lubrifluid attachment 1
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Lubrifluid button down for 1 second
  • Then, run an operating test for 30 seconds at a low speed to remove any surplus lubricant
  • Store immediately: store the instruments with the tip pointing downwards so that any oil residues can flow out

STERILISATION

A.PLACE THE CONTRA-ANGLE IN A STERILISATION BAG

B. STERILISE IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS

Instruments bearing the “135°C” symbol can be sterilised in an autoclave

Only sterilise instruments which have been cleaned and lubricated

Downloads

BROCHURE

MANUAL

MAINTENANCE

IMAGES